Shenzhen Eurostars Technology Co., Ltd.
Guangdong, China
Diamond Member Since 2015
Audited Supplier
Manufacturer/Factory & Trading Company
Sample Available
OEM/ODM Service
Factory Tour
Ground Source Heat Pump Air Conditioner Heat Reclaim Heat Pump
Reference FOB Price: | US $22,000.00-185,000.00 / Piece |
---|---|
Min. Order: | 1 Piece |
Energy Efficiency Grade: | Two |
---|---|
Heat Temperature: | 50-70°C |
Work Environment: | Common Heat Pump |
Heat Source: | Water-source |
Heating Type: | Circulating Heat |
Application: | Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons |
Basic Info
Model NO.
ESGW130DOQN
Certification
CE, CCC, SGS
Heat Pump Compresor
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson
Heat Pump Dry Filter
Danfoss
Optional
Partial Heat Recovery
Compressor Quantity
1 or 2
Transport Package
Standard Export Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc.
HS Code
8418692090
Production Capacity
1000 PCS/Year
Product Description
Ground Source Heat Pump Air Conditioner Heat Reclaim Heat Pump
1.Brief introduction-Eurostars water source heat pump with heat recovery
a)Underground water source
b)Intellectualized control system and low noise
c)High efficient and energy saving
d)Easy operation and installation
e)Compact exterior
f)High quality
g)Competitive price
h)Cooling in summer, Heating in Winter, Sanitary hot water all year round.
2.Unit Features-Eurostars water source heat pump with heat recovery
1).Heating capacity ranged from 212Kw to 3407 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc
6). Strong unit base frame ensured the equipment stable operation
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
3.Technical parameter-water cooled water source heat pump with heat recovery
Please ask salesman for detailed complete data
or visit our website: eurostarschiller.en.made-in-china.com
(1).Rated Cooling Capacity Based on: Underground water in/outlet temp 18ºC/29ºC;Chilled water in/outlet temp. 12ºC/7ºC, Fouling factor: 0.088.°C/KW.
(2).Rated heating capacity based on:Underground water inlet temp. 15°C;Hhot water inlet temp. 40°C.
4.Eurostars water cooled water source heat pump water chiller protection devices
1)Phase reversion protection,
2)Overload current protection,
4)Phase lack protection,
5)Discharge air temp. protection,
6)Low&High pressure protection,
7)Reserved water flow protection interface,
8)Low temp. protection.
5.Eurostars water source heat pump chiller series
-Commercial Water Source Heat Pump Chiller
-Scroll type water cooled water source heat pump
-Screw type water cooled water source heat pump
-Flooded type water cooled water source heat pump
-Commercial Air Cooled Heat Pump Chiller
-Scroll type air cooled air source heat pump
-Screw type air cooled air source heat pump
-Cooling&Heating&Sanitay hot water
-Air source heat pump with heat recovery
-Water source heat pump with heat recovery
1.Brief introduction-Eurostars water source heat pump with heat recovery
a)Underground water source
b)Intellectualized control system and low noise
c)High efficient and energy saving
d)Easy operation and installation
e)Compact exterior
f)High quality
g)Competitive price
h)Cooling in summer, Heating in Winter, Sanitary hot water all year round.
2.Unit Features-Eurostars water source heat pump with heat recovery
1).Heating capacity ranged from 212Kw to 3407 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc
6). Strong unit base frame ensured the equipment stable operation
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
3.Technical parameter-water cooled water source heat pump with heat recovery
Please ask salesman for detailed complete data
or visit our website: eurostarschiller.en.made-in-china.com
Screw-type Water Source Heat Pump with Heat Recovery (two compressors) | ||||||||||
Model ESGW | 055DOQN | 130DOQN | 140DOQN | 195DOQN | 285DOQN | 315DOQN | 335DOQN | 350DOQN | ||
Rated Cooling Capacity | Cooling Capacity (KW) | 212 | 497 | 543 | 742 | 1094 | 1210 | 1290 | 1349 | |
Cooling Capacity (USRT) | 60.30 | 141.35 | 154.44 | 211.04 | 311.15 | 344.14 | 366.89 | 383.67 | ||
Input Power (KW) | 37.8 | 83.8 | 92.0 | 119.5 | 175.2 | 194.9 | 206.7 | 217.7 | ||
Rated Heating Capacity | Heating Capacity (KW) | 253 | 585 | 640 | 865 | 1126 | 1411 | 1501 | 1573 | |
Heating Capacity (USRT) | 71.96 | 166.38 | 182.03 | 246.02 | 320.25 | 401.31 | 426.91 | 447.38 | ||
Input Power (KW) | 53.4 | 117.8 | 129.2 | 167.0 | 245 | 272.3 | 288.6 | 304.2 | ||
Refrigerant | R407C | |||||||||
Compressor | Semi-hermetic Screw Type | |||||||||
Power Supply | 3φ-380V-50HZ | |||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Reserved water flow protection interface. | |||||||||
Number of Refrigeration Circuit | 2 | |||||||||
Capacity Control (%) | 0,25,37.5,50,62.5,75,87.5,100 | |||||||||
Refrigerant Charge (Kg) | 34 | 80 | 87 | 118 | 179 | 194 | 209 | 219 | ||
Chilled Water | Temp of inlet/outlet water | 12ºC/7ºC | ||||||||
Water Side Max Pressure (MPa) | 1 | |||||||||
Dia.of Pipe (inch) | 3" | 5" | 5" | 5" | 6" | 6" | 8" | 8" | ||
Water Flow (m3/h) | 36.5 | 85.5 | 93.4 | 127.6 | 188.2 | 208.1 | 221.9 | 232.0 | ||
Pressure drop (kPa) | 29 | 39 | 49 | 40 | 43 | 48 | 47 | 51 | ||
Under Ground Water | Temp of inlet/outlet water | 18ºC/29ºC | ||||||||
Water Side Max Pressure (MPa) | 1 | |||||||||
Dia.of Pipe (inch) | 3" | 4" | 5" | 5" | 4"×2 | 5"×2 | 5"×2 | 5"×2 | ||
Water Flow (m3/h) | 19.8 | 45.8 | 50 | 67.6 | 88 | 110.3 | 117.3 | 123 | ||
Pressure drop (kPa) | 41 | 43 | 44 | 45 | 46 | 47 | 50 | 53 | ||
Running Noise dB(A) | 76.1 | 82.0 | 82.2 | 83.4 | 88.2 | 89.3 | 89.6 | 89.9 | ||
Total weight (Kg) | 1410 | 2260 | 2540 | 2930 | 3740 | 3950 | 4320 | 4810 | ||
Running Weight (Kg) | 1790 | 2970 | 3330 | 3920 | 4830 | 5140 | 5540 | 5750 | ||
Heat Recovery Parameters | ||||||||||
Refrigerant Charge (Kg) | 34 | 80 | 87 | 118 | 179 | 194 | 209 | 219 | ||
Heat Reclaimed Volume (KW) | 63.6 | 149.1 | 162.9 | 222.6 | 328.2 | 363.0 | 387.0 | 404.7 | ||
Heat Recovery unit | Water Side Max Pressure (MPa) | 1 | ||||||||
Dia.of Pipe (inch) | 2" | 2-1/2" | 2-1/2" | 2-1/2" | 3" | 3" | 3" | 3" | ||
Water Flow (m3/h) | 10.9 | 25.6 | 28.0 | 38.3 | 56.5 | 62.4 | 66.6 | 69.6 | ||
Pressure drop (kPa) | 23 | 26 | 26 | 29 | 34 | 35 | 38 | 39 | ||
Total weight (Kg) | 1550 | 2510 | 2810 | 3330 | 3910 | 4470 | 4910 | 5360 | ||
Running Weight (Kg) | 1950 | 3240 | 3580 | 4280 | 4970 | 5660 | 5920 | 6160 | ||
Dimension L×W×H | Detailed dimensions are according to the actual finished product sizes. |
Screw-type Water Source Heat Pump with Heat Recovery (two compressors) | |||||||||
Model ESGW | 405DOQN | 445DOQN | 480DOQN | 535DOQN | 675DOQN | 790DOQN | 885DOQN | ||
Rated Cooling Capacity | Cooling Capacity (KW) | 1570 | 1723 | 1850 | 2064 | 2592 | 3053 | 3407 | |
Cooling Capacity (USRT) | 446.53 | 490.05 | 526.17 | 587.03 | 737.20 | 868.32 | 969.00 | ||
Input Power (KW) | 250.6 | 275.3 | 293.4 | 327.2 | 412.7 | 483.2 | 533.9 | ||
Rated Heating Capacity | Heating Capacity (KW) | 1825 | 2005 | 2147 | 2396 | 3013 | 3543 | 3945 | |
Heating Capacity (USRT) | 519.06 | 570.25 | 610.64 | 681.46 | 856.94 | 1,007.68 | 1,122.01 | ||
Input Power (KW) | 350.2 | 384.6 | 409.8 | 457.1 | 576.5 | 675.1 | 745.8 | ||
Refrigerant | R407C | ||||||||
Compressor | Semi-hermetic Screw Type | ||||||||
Power Supply | 3φ-380V-50HZ | ||||||||
Safety Protection | Phase reversion protection, Phase lack protection, Overload current protection, Discharge air temp. protection, Low & High pressure protection, Low temp. protection, Reserved water flow protection interface. | ||||||||
Number of Refrigeration Circuit | 2 | ||||||||
Capacity Control (%) | 0,25,37.5,50,62.5,75,87.5,100 | ||||||||
Refrigerant Charge (Kg) | 255 | 281 | 300 | 336 | 414 | 486 | 558 | ||
Chilled Water | Temp of inlet/outlet water | 12ºC/7ºC | |||||||
Water Side Max Pressure (MPa) | 1 | ||||||||
Dia.of Pipe (inch) | 8" | 8" | 8" | 8" | 8" | 10" | 10" | ||
Water Flow (m3/h) | 270.0 | 296.4 | 318.2 | 355.0 | 445.8 | 525.1 | 586.0 | ||
Pressure drop (kPa) | 55 | 71 | 69 | 66 | 64 | 71 | 76 | ||
Underground Water | Temp of inlet/outlet water | 18ºC/29ºC | |||||||
Water Side Max Pressure (MPa) | 1 | ||||||||
Dia.of Pipe (inch) | 5"×2 | 5"×2 | 5"×2 | 6"×2 | 6"×2 | 8"×2 | 8"×2 | ||
Water Flow (m3/h) | 142.7 | 156.7 | 167.9 | 187.3 | 235.5 | 276.9 | 308.4 | ||
Pressure drop (kPa) | 59 | 61 | 67 | 74 | 76 | 80 | 85 | ||
Running Noise dB(A) | 90.1 | 90.3 | 90.6 | 91.4 | 93.3 | 93.8 | 94.2 | ||
Total weight (Kg) | 5270 | 5680 | 5890 | 6110 | 7380 | 8010 | 8550 | ||
Running Weight (Kg) | 5970 | 6190 | 6500 | 6810 | 8420 | 9180 | 9720 | ||
Heat Recovery Parameters | |||||||||
Refrigerant Charge (Kg) | 255 | 281 | 316 | 354 | 436 | 512 | 584 | ||
Heat Reclaimed Volume (KW) | 471 | 516.9 | 555 | 619.2 | 777.6 | 915.9 | 1022.1 | ||
Heat Recovery unit | Water Side Max Pressure (MPa) | 1 | |||||||
Dia.of Pipe (inch) | 4" | 4" | 4" | 4" | 5" | 5" | 5" | ||
Water Flow (m3/h) | 81.0 | 88.9 | 95.5 | 106.5 | 133.7 | 157.5 | 175.8 | ||
Pressure drop (kPa) | 42 | 42 | 43 | 43 | 43 | 43 | 43 | ||
Total weight (Kg) | 5820 | 6290 | 6620 | 6840 | 7610 | 8440 | 8980 | ||
Running Weight (Kg) | 6470 | 6790 | 7220 | 7440 | 8660 | 9520 | 10080 | ||
Dimension L×W×H | Detailed dimensions are according to the actual finished product sizes. |
(1).Rated Cooling Capacity Based on: Underground water in/outlet temp 18ºC/29ºC;Chilled water in/outlet temp. 12ºC/7ºC, Fouling factor: 0.088.°C/KW.
(2).Rated heating capacity based on:Underground water inlet temp. 15°C;Hhot water inlet temp. 40°C.
4.Eurostars water cooled water source heat pump water chiller protection devices
1)Phase reversion protection,
2)Overload current protection,
4)Phase lack protection,
5)Discharge air temp. protection,
6)Low&High pressure protection,
7)Reserved water flow protection interface,
8)Low temp. protection.
5.Eurostars water source heat pump chiller series
-Commercial Water Source Heat Pump Chiller
-Scroll type water cooled water source heat pump
-Screw type water cooled water source heat pump
-Flooded type water cooled water source heat pump
-Commercial Air Cooled Heat Pump Chiller
-Scroll type air cooled air source heat pump
-Screw type air cooled air source heat pump
-Cooling&Heating&Sanitay hot water
-Air source heat pump with heat recovery
-Water source heat pump with heat recovery