Gold Member Since 2015
Audited Supplier
Shenzhen Eurostars Technology Co., Ltd.

Fan Coil, Vertical Exposed Fan Coil, Fan Coil Unit manufacturer / supplier in China, offering Three Speed Control Vertical Exposed Floor Standing Mounted Fan Coil Unit, Water Cooling Air Handling Unit, Sauna Room Use 75c High Water Temp Heat Pump and so on.

(/ )

Supplier Homepage Product Fan coil/Fan Coil Unit Three Speed Control Vertical Exposed Floor Standing Mounted Fan Coil Unit

Three Speed Control Vertical Exposed Floor Standing Mounted Fan Coil Unit

FOB Price: US $115-300 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $115-300/ Piece
Get Latest Price
Production Capacity: 10000PCS/Year
Transport Package: Standard Export Packing, Such as Cartons
Payment Terms: L/C, T/T, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: EST1000VE2
  • Air Tube Material: Galvanized Sheet
  • Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH
  • Application Fields: Villa/School/Restaurant/Hotel Room
  • Lifetime: >20 years
  • Condition: New
  • Pipe System: 2pipe/4pipe
  • Air Outlet Way: Top/Side/Front
  • Specification: CE Approval
  • HS Code: 84159010
  • Type: Fan Coil Unit
  • Corrosion Durability: Higher
  • Noise Level: Low
  • Mounting: Floor Standing Mounted
  • Certification: CE
  • Color: White
  • Air Outlet Static Pressure: 0,12, 30,50PA
  • Trademark: Eurostars
  • Origin: Guangdong, Prc
Product Description
Three Speed Control Vertical Exposed Floor Standing Mounted Fan Coil Unit 

1. Vertical exposed fan coil unit features:
(1)Low noise; (2) High efficient and energy saving; (3) Strong air flow; (4) Flexible installation; (5) Easy operation.

In central air conditioner system, Eurostars vertical exposed floor standing fan coil continuously exchanges the indoor air with cool & heat supplied by chiller system, in order to adjust the room temperature and humidity. Vertical floor standing fan coil is widely appliated in bureaux, business building, superstore, hotel, hospital, bank, apartment and amusement place.

2. Vertical floor standing fan coil unit nomenclature

ES  T   1000    VE2      T     R    A    O   
1    2      3          4         5      6     7    8   
1: ES Eurostars
2 :T Terminal series
3 :1000 Rated air flow: CFM
4 :VE2 Ceiling exposed floor mounted and the number of tube system
5 :T Coil type:  T-2C0H (Note: C-Cold water coil; H-Hot water coil)                                    
6 :R Connection pipe direction: R-Right (face to air outlet)  L-Left (face to air outlet)
7: A Power supply: A-220V-50HZ; K-208~230V-60HZ; N-115-60HZ; W-265~277V-60HZ
8 :O Sales region: O-Other regions;  C-Mainland China

3. Eurostars vertical exposed fan coil techinal specification
Please ask salesman for detailed complete data or visit our website:
www.eurostarschina.com

Vertical Exposed Fan Coil Unit (2 pipe system)
Model EST200VE2300VE2400VE2500VE2600VE2800VE21000VE21200VE21400VE2
Air flow (m³/h)
(0 Pa,12Pa,30Pa,50Pa 
Static Pressure)
High 34051068085010201360170020402380
Medium 2553835106387651090127515301785
Low 17025534042551075085010201090
Rated cooling capacityW19402700415046206100755090501110012910
BTU6621921514164157682081925768308883788444062
Rated heating capacity W3110432063207620933011940143101776020660
BTU106141474421570260073184340751488406061570513
Motor power input W0,12Pa121620253225+1232+1632*235*2
30,50Pa162025325025+1650+2050*260*2
Noise dB(A)0,12Pa37 39 41 43 45 47 48 50 52 
30Pa40 42 44 46 47 49 50 52 54 
50Pa42 44 46 47 49 51 52 54 56 
Water flow0,12Pa m3/h0.390 0.546 0.719 0.877 1.033 1.511 1.675 2.013 2.406 
30,50Pa m3/h0.413 0.578 0.762 0.930 1.095 1.601 1.775 2.133 2.586 
 Water resistance kPa101215182123243039
Heat exchangerTypecopper tubes with shutter-type aluminum fins
Working pressure1.6MPa
Testing pressureAirtightness test under pressurized water: 3.3MPa
FanType Forward-pitched multi-wing centrifugal fan with double-suction impellers
 made from zinc-plated steel plates
Qty112223344
MotorTypeSingle-phase capacitive motor equips with fine ball bearing, low noise and long service life
Qty111112222
Power supply220V/1PH/50HZ
Protection gradeIP20
Insulation classB
Pipe Inlet/outlet water pipeZG 3/4 "  internal thread
Condensation water pipeZG 3/4"  external thread
 Net  weight Kg24.00 24.00 28.00 30.00 33.00 42.00 45.00 50.00 54.00 
Note:
(1)Cooling: Inlet air temperature DB 27ºC,WB 19.5ºC; Chilled water inlet/outlet temp. 7ºC/12ºC.
(2)Heating: Inlet air temperature DB 21°C, heating water inlet temperature  60°C (tested by the same water flow with cooling condition).
(3)The noise level is measured in: background noise 11.5Db(A) semi-anechoic room as per GB/T19232-2003.
(4)Rated air flow is tested in standard air condition with DB 20ºC.
(5)Specifications are subject to product improvement and change without notice.

4.Vertical floor fan coil unit quotation remarks
(1)Packing: Standard export package
(2)Delivery Day: 10~25 working days after deposit is confirmed
(3)Delivery term: CIF,FOB or CNF EX-Work are welcomed
(4)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
(5)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
(6)Validity: 20 days
(7)Payment currency: USD

5. Eurostars fan coil unit series
(1)Wall mounted split fan coil unit
(2)Ceiling floor fan coil unit
(3)Horizontal concealed ceiling duct fan coil unit
(4)Horizontal exposed fan coil unit
(5)Ceiling cassette fan coil unit
(6)Vertical exposed fan coil unit
(7)Vertical concealed fan coil unit
Send your message to this supplier
Avatar
Mr. John
Sales Manager
*From:
To: Mr. John
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now