• Slim Ceiling Concealed DC Ec Fan Coil Unit
  • Slim Ceiling Concealed DC Ec Fan Coil Unit
  • Slim Ceiling Concealed DC Ec Fan Coil Unit
  • Slim Ceiling Concealed DC Ec Fan Coil Unit
  • Slim Ceiling Concealed DC Ec Fan Coil Unit
  • Slim Ceiling Concealed DC Ec Fan Coil Unit

Slim Ceiling Concealed DC Ec Fan Coil Unit

Type: Fan Coil Unit
Air Tube Material: Galvanized Sheet
Corrosion Durability: Higher
Operating Voltage: 110V/220~240V-50Hz/60Hz-1pH
Noise Level: Low
Application Fields: Restaurant/Hotel Room/Villa
Samples:
US$ 150/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
EST-HC series
Mounting
Ceiling Concealed
Lifetime
>20 years
Certification
CE
Condition
New
Air Outlet Static Pressure
0, 12, 30PA
Motor
BLDC, Ec
Pipe System
Two Pipe System
Production Time
20 Days for Bulk Order
Air Return
Backward/Downward
Rows
2 and 3 Rows
Main Usage
Chiller, Heat Pump, Underfloor Heating
Transport Package
Standard Export Packing, Such as Cartons
Specification
CE Approval
Trademark
ESACIR
Origin
Guangdong, Prc.
HS Code
8415830000
Production Capacity
10000 PCS/Year

Product Description

Slim Ceiling Concealed DC EC Fan Coil Unit

1. Ceiling concealed DC fan coil brief description 
Fan coil unit is the terminal of central air conditioning system.It consists of centrifugal fan and copper tube heat exchanger.The ceiling concealed fan coil unit can be embedded in the ceiling and merged with interior decoration. Only exposing tuyere, which save space and easy maintenance. Widely used in hotels, restaurants, factories, hospitals, exhibition hall, shopping malls, office rooms and other industrial and civil construction of the combined air-conditioning system to meet the cooling, heating and other requirements.

2. Slim DC fan coil main applications
(1)Showroom
(2) Shopping mall
(3) Restaurant & Bar
(4) Hotels
(5) Offices
(6) Building
(7) Clean room
(8) Other fields

3. Ceiling concealed slim DC fan coil unit main components
(1) Fan 
Fans are made of plastic centrifugal type. All fans are statically and dynamically balanced.
(2) Motor
DC Single-phase motors are suitable for different voltages, such as 110V, 115V, 120V, 220V, 230V, 240V. All motors have 10 percent voltage utilization range and wired to unit terminal box. Motors are designed for long life.
(3) Drain pan
Dray pan is integrally attached to coil casings and ended with drain hose. All pans are made of  foam.
(4) Water coil
Coils are 2 and 3-row as standard design together.  High efficient hydrophilic aluminum fins are mechanically bonded to seamless copper tubes. All coils are specifically designed and circuited for water use. All coils are tested at 3.3MPa.
(5) Casing
Casing are constructed of heavy gauge steel. Interior surface of unit panels are acoustically and thermally insulated with polyethylene foam.
Units are furnished as standard with a 1 inch duct collar to facilitate connection of the supply air duct.
(6) Return air plenum (optional)
The fan coil unit shall be factory installed return air plenum that encloses the fan section of the unit. No field fabrication is required. The return air arrangement is adaptable between bottom or rear return of the plenum.
(7) Washable filter (optional)
Filter should be accessible from return air grille.

4. Ceiling concealed slim DC fan coil unit features
(1)200mm slim design, beautiful appearance, save the space of ceiling
The fan coil is only 200mm thickness, which is suitable to installed in a height-limited ceiling.
(2)Left/right pipe connection direction is optional
The water pipe connection direction can be customized, it will benefit to short the installation cost.
(3)Air return box is standard, and air direction can be exchange between side return and bottom return
(4)Use plastic fan, which can offer softer air flowing and reduce the noise level.
(5)Air volume range is from 200CFM to 700CFM, which is fully satisfy to the necessary of home using.
(6)High efficiency
Adopt good quality heat exchanger and fan, which is benefit to the heat exchanging capacity and efficiency.
(7)Drain pump is optional
750 mm lift drain pump is optional to built-in the fan coil, the controlling of drain pump is also built-in. Water float switch is standard for the fan coil which built-in drain pump to prevent the leaking of draining.

5. Ceiling horizontal concealed fan coil unit techinal specification
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Type DC motor slim concealed fan coil
Max air flow 200~700CFM(EST200HC2~800HC2)
Static pressure 12Pa
Cooling capacity 2~6.3KW
Heating capacity 3.2~10.2KW
Fan type Plastic centrifugal fan
Motor DC motor
Application Commercial buildings,Hotel, Villa, etc.
 
6. Fan coil unit series
Slim Ceiling Concealed DC Ec Fan Coil Unit

Ceiling concealed fan coil unit
High ESP ducted fan coil unit
Universal concealed fan coil unit
Floor standing exposed fan coil unit
Ultra thin exposed fan coil unit
Ceiling exposed fan coil unit
Ceiling cassette fan coil unit
Ceiling exposed & floor standing fan coil unit
Wall mounted fan coil unit
 
7.About us:
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Webiste 1: http://eurostarschiller.en.made-in-china.com/
Website 2: http://eurostarschiller.en.made-in-china.com/
 
Instagram: https://eurostarschiller.en.made-in-china.com
Facebook: https://eurostarschiller.en.made-in-china.com
Youtube https://eurostarschiller.en.made-in-china.com

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

Slim Ceiling Concealed DC Ec Fan Coil Unit
Slim Ceiling Concealed DC Ec Fan Coil Unit

Slim Ceiling Concealed DC Ec Fan Coil Unit

8. How to choose the fan coil?
(1) Firstly need to know the application site, for example, hotel room generally choose ceiling concealed fan coil, restaurant generally choose ceiling cassette fan coil, it depends on site requirements.
(2) If need to calculate cooling capacity, please get the acreage data.
(3) Confirm the pipe system: 2 pipe or 4 pipe according to the cooling and heating source.

9. Our warranty, technical support and failure claim procedures
(1) Warranty
a. Eurostars HVAC units delivered to customers are carefully examined and tested, with 48 hours trouble-free trial operation.
b. Eurostars HVAC units enjoy 1~1.5 years guarantee ever since B/L date. 
(2)Technical support
a. Eurostars provide full technical support and training courses after equipment installation and commissioning.
b. 7*24 hours phone assistance on technical support.
c.  Eurostars provide overseas guide installation,but not for free.
(3)Failure claim procedures 
a. Detailed written failure description is required by fax or by mail, indicating the relevant equipment information and detailed description of failure.
b. Relevant pictures are required for failure confirmation.
c. Eurostars engineering and after-sales service team will check and form a diagnosis report.
d. Further trouble-shooting solutions will be offered to customers within 24 hours after receiving the written description and pictures.
Slim Ceiling Concealed DC Ec Fan Coil Unit

 
10. Fan coil unit package and delivery
For bulk order, our standard package is carton packing for fan coil, for safe delivery and easy to load/unload, we will stack several layers together with plastic film and packing straps tightly onto the plywood or plastic pallets.
For sample order, we generally use plywood box or honeycomb cardboard to protect.
Slim Ceiling Concealed DC Ec Fan Coil Unit
Slim Ceiling Concealed DC Ec Fan Coil Unit
Slim Ceiling Concealed DC Ec Fan Coil Unit

11. Ceiling concealed fan coil installation instruction
(1) Air duct must be fireproof regulations for buildings.
(2) For horizontal air supply, N≥150 MM; if air duct is longer than 1 m, N≥200 mm.
(3) Size of M depends on air duct installation. Pressure loss of circulatory air must be consistent with outlet static pressure of the unit.
Slim Ceiling Concealed DC Ec Fan Coil Unit

12. Fan coil unit projects
We exported fan coils to Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Mexico, Argentina, etc..
Slim Ceiling Concealed DC Ec Fan Coil Unit
Slim Ceiling Concealed DC Ec Fan Coil Unit

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now