Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220~460V-50Hz/60Hz-3pH
Compressor Number: 1,2,3,4,5
Noise Level: Low
Samples:
US$ 1500/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA Series
Application Fields
Chemical
Application Machine
Precision Machine Tool
Certification
CE
Condition
New
Compressor
Copeland, Danfoss, SANYO
Cabinet
Anti-Corrosion
Expansion Valve
Danfoss, Emerson
Controller
Microcomputer Control Punp
Tank
Stainless Steel, Unpressurized
Solenoid Valve
Optional Castel
Evaporator
Plate, Shell Tube, Coil in Tank
Refrigerant
R407c, R22, R134A, R404A
Fan
Axial
Service
OEM, ODM
Color
Blue White
Condenser
Aluminum Finned Copper Tube
Water Pump
Cnp
Transport Package
Wooden Case
Specification
Scroll Cooling Only
Trademark
ESACIR
Origin
Shenzhen
HS Code
8418692090
Production Capacity
3000 Units Per Year

Product Description

Water Chiller Air Cooled Industrial Chiller For Laboratory Refrigeration

1. Eurostars air cooled water chiller main components

(1)Intelligent digital controller(PLC controller optional)
(2)Copeland scroll
(3)Stainless steel/copper braze plate heat exchanger (shell tube optional)
(4)Large copper condensing coil with aluminum fins
(5)Powder Coated, Heavy Gauge, Steel Cabinet (Stainless steel cabinet is optional)
(6)Rugged Stainless Steel Centrifugal Pumps
(7)Thermal expansion valve (electrical expansion valve is optional)
(8)Solenoid valve is optional;
(9)Standard insulated stainless steel unpressurized tank (pressurized tank is optional)

Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

2. Eurostars air cooled industrial chiller characterisitics
(1)R22,R407c, R134a, R404a,R410A are available;
(2)Adopt international brands compressors : SANYO, COPELAND, DANFOSS, etc ;
(3)High-quality stainless steel multi-stage centrifugal pumps and stainless steel tanks(OPTIONAL);
(4)High efficiency finned tube condenser, ensure that the chiller can work properly;
(5)Using international brand Electrical components, and famous branded microcomputer temperature controller ;
(6)Multiple protection devices; ensure stable operation for many years;
(7)Wide variable range of frozen water, to meet different user requirements;
(8)Using ethylene glycol as the carrier refrigerant is more or less the freezing water temperatures as low as -15 °C(optional);
(9)Mounted Casters for small models ,tank level alarm/switch.

3. Air cooled industrial chiller applications
Air-cooled chillers are intended for outdoor installation and operation. Air-cooled machines are directly cooled by ambient air being mechanically circulated directly through the machine's condenser coil to expel heat to the atmosphere. No remote cooling tower is typically required with packaged air-cooled chillers. Eurostars air cooled industrial chillers are mainly applied in the following fields:
Induction heating equipment, diathermy equipment
High frequency, medium frequency power supply, IGBT quenching equipment
Die-casting machines, injection molding machines
Rectifier equipment, resistance welding machine
Single crystal furnace, continuous casting mold machine, glass melting furnace
Food, chemical, air compressors, central air conditioning

Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

4. Eurostars air cooled industrial chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit
Model      ESSA- 01ISSN 02ISSN 03ISTN 04ISTN 05ISTN 06ISTN 08IDTN 10IDTN 12IDTN
Item NO. 1 2 3 4 5 6 8 10 12
Rated Cooling Capacity KW 2.76  5.72  8.96  11.31  14.12  17.24  22.62  28.24  34.48 
USRT 0.78  1.63  2.55  3.22  4.02  4.90  6.43  8.03  9.81 
×1000 kcal/h 2.37  4.92  7.71  9.73  12.14  14.83  19.45  24.29  29.65 
Air Cooled Chiller Unit
Model      ESSA- 15IDTN 20IDTN 25IDTN 30IDTN 40IQTN 50IQTN 60IQTN
Item NO. 15 20 25 30 40 50 60
Rated Cooling Capacity KW 43.22 58.2 71.18 87.3 87.78 116.4 142.36 177.95 175.56
USRT 12.29  16.55  20.24  24.83  24.97  33.11  40.49  50.61  49.93 
×1000 kcal/h 37.17  50.05  61.21  75.08  75.49  100.10  122.43  153.04  150.98 
Remarks:
(1) Rated Cooling Capacity Based on:Evaporating temperature 7ºC;Condensing temperature 50ºC,Ambient DB=35ºC.
(2)Chilled Water Range: 5~25ºC;

5. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
(2)Compressor motor overheat protection
(3)Discharge temperature overhigh protection
(4)High&low pressure protection
(5)Returning water overheat protection
(6)Low water flow/level protection
(7)Phase protection
(8)Anti-freezing protection

6. Industrial chiller flow chart 
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

 
(1)Compressor (2)High pressure gauge (3)Condenser
(4)Dry filter (5)Thermal expansion valve (6)Water supplement
(7)Evaporator (8)Low pressure gauge (9)Water tank
(10)Drainage (11)Chilled water in and outlet (12)Water pump

7.Industrial Chiller Installation Precautions
Although Eurostars provides chiller installation guidance service, if you already have some experiences in chiller operation and installation, you can choose to proceed by yourself to save labor cost and time.
But pay attention to a few more details, the chiller will return you better performance and longer service life. 
Here are the precautions that you need to know before proceed:
(1)Selection of installation location.
For air cooled chillers,we need an open space with good ventilation. Make sure there is no barriers or walls within 1m around it, otherwise there will be trouble for air flow and heat dissipation. The point is we need to make sure the heat out from the chiller can be removed outside, instead of circulating within a small space.The distance to block also ensures space for maintenance. If you are planning to install an air cooled chiller in a space with poor ventilation, you need to consider mounting air duct on top of the chiller near the condenser fans, so to make sure heat removal.

In below picture, Case1 is a chiller located in drafty condition, Case 2 is a chiller located in poor ventilation environment.
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

For water cooled chillers, we just need to reserve enough space for maintenance, as the heat from the chiller is removed through water to the cooling tower.
(2)Ground for locating the chiller.
 Industrial chiller must be placed on solid and level concrete floor which is able to support the weight of the chiller. The levelness of the floor should be within 6mm. Chillers vibrate when running, if the floor is not solid nor flat, the chiller will easily displace, especially for portable chiller with casters. Rough ground will amplify the vibration of chiller, which will lead to serious troubles after long time running.
 
For a large chiller unit, say models higher than ESSA-15IDTN, we need to build concrete foundation for it. It is necessary to make 50-100mm absorbing gap fill with sands or pitch all around the foundation. On the foundation, there should be bolt holes for fastening the chiller base and concrete foundation together.
 
After the above things are done, let's put the chiller on the foundation. Then we need a level meter to check if there is any incline. If there is, put parallels between chiller base and concrete foundation to adjust it.

(3)Pipe, wire and filter preparation
*In a Eurostars chiller specification sheet, there is connection size and max amps for the unit. Correctly select the pipe and wire size by referring to it.
*If you are not so confident with the water quality in your location, filtration is a necessity to avoid the chiller water circuit from trouble.Y type filter is suggested.
*Make sure you are clear that which port you should connect to. Although there will be sign of inlet or outlet of every Eurostars chiller, double check it please.
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

 

8. Why choose Eurostars?
(1)Designing
*Solid external structure design to make sure a chiller runs on a strong foundation
*Strict calculation and repeated trials for every component before putting it into a Eurostars product
*Rational internal structure design to ensure stable performance of every part
(2)Manufacturing
*Experienced production team consists of senior workers with more than 10 years experience in industrial refrigeration area
*Established production process is strictly applied on every product, which is detailed to every welding spot, pipe connection and screw fastening
(3)Quality control
*120+ incoming inspection rules
*80+ final QC rules
*72hr 18 Bar nitrogen pressure holding testing
*48hr running test
(4)Unit built-in protection
*Motor overload protection for compressor, pump and condenser fan
*Compressor motor overheat protection
*Discharge temperature overheat protection
*High&low pressure protection
*Returning water overheat protection
*Low water flow/level protection
*Phase protection
*Anti-freezing protection
(5)Warranty
*12 months warranty on every unit
*Extended warranty up to 5 years

9. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

10. Our factory view
Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration
Chiller production at our previous location as below
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

10. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.

Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

11. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration
Water Chiller Air Cooled Industrial Chiller for Laboratory Refrigeration

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now