Air to Water Heat Pump with Double Compressor

Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Circulating Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Certification: CE
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESGA-120DHTS
Heat Pump Compresor
Taiwan Hanbell
Heat Pump Expansion Valve
Emerson
Heat Pump Dry Filter
Danfoss
Transport Package
Standard Export Package
Specification
CE
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8418692090
Production Capacity
2000PCS/Year

Product Description

1.Brief introduction-Eurostars air cooled air source heat pump
a)Ambient temp range:-5~43C(-25C~43C)
b)Intellectualized control system and Low Noise
c)High Efficient and Energy Saving
d)Easy Operation and Installation
e)Compact Exterior
f)High quality
g)Competitive price

2.Unit Features-Eurostars air cooled air source heat pump

1).Heating capacity ranged from 130Kw to 790 Kw.
2). Adopt good quality famous brand Hanbell screw compressor,high efficiency, low noise, less wearing and long life
3).Both Evaporator and Condenser are high quality and high efficiency
4). World famous brand parts: such Emerson expansion valve, FUJI contactor other brand like PUNP, Schneider.
5). Can be widely used in different area,such as Massage center, Hospital, Hotel, School, etc
6). Strong unit base frame ensured the equipment stable operation
7). Adopt leading brand PLC or SCM controller
8). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.


3.Technical parameter-air cooled air source heat pump
Please ask salesman for detailed complete data or visit our website.

Model     ESGA- 30SHTS 45SHTS 60SHTS 70SHTS 80SHTS 85SHTS 95SHTS
Rated Cooling Capacity Cooling Capacity (KW) 119 170 228 269 310 337 369
Cooling Capacity (USRT) 33.85 48.35 64.85 76.51 88.17 95.85 104.95
Comp. Input Power (KW) 34.7 47.7 63.2 71.2 82.4 89.9 99.9
Rated Heating Capacity Heating Capacity (KW) 130 183 246 285 330 357 395
Heating Capacity (USRT) 36.97 52.05 69.97 81.06 93.86 101.54 112.34
Comp. Input Power (KW) 32.6 44.8 59.6 67.0 77.6 84.6 94.1
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface
Number of Refrigeration Circuit 1
Capacity Control (%) 0, 66, 100 0, 50, 75, 100
Refrigerant Charge (Kg) 30 42 56 68 78 84 93
Air Cooled Heat Exchanger Ripple Aluminum Fins Around Copper Pipe
Water Cooled
Heat Exchanger
Dia.of Pipe (inch) 2-1/2" 3" 3" 3" 4" 4" 4"
Water Side Max Pressure  (MPa) 1
Chilled  Water Flow(m3/h) 20.47 29.24 39.22 46.27 53.32 57.96 63.47
Water Pressure Drop (kPa) 28 33 48 55 61 64 66
Flow of Hot Water(m3/h) 22.36 31.48 42.31 49.02 56.76 61.40 67.94
Axial Fan Air Flow×1000m3/h 56.8 80.4 85.2 120.6 120.6 160.8 160.8
Power×Qty (KW) 1.2×4 2.0×4 1.2×8 1.2×8 1.2×8 2.0×8 2.0×8

Model     ESGA- 110DHTS 120DHTS 140DHTS 150DHTS 160DHTS 175DHTS 190DHTS
Rated Cooling Capacity Cooling Capacity (KW) 415 456 537 568 620 672 740
Cooling Capacity (USRT) 118.03 129.69 152.73 161.55 176.34 191.13 210.47
Comp. Input Power (KW) 116.2 126.4 142.4 149.8 164.8 179.8 199.8
Rated Heating Capacity Heating Capacity (KW) 447 490 570 602 659 715 789
Heating Capacity (USRT) 127.13 139.36 162.12 171.22 187.43 203.36 224.40
Comp. Input Power (KW) 109.3 119.1 134.0 141.0 155.2 169.3 188.3
Refrigerant R22
Power Supply 3φ-380V-50HZ
Safety Protection Phase reversion protection, Phase lack protection, Overload current protection,
Discharge air temp.  protection, Low & High pressure protection,
Low temp.  protection, Reserved water flow protection interface.
Number of Refrigeration Circuit 2
Capacity Control (%) 0, 25, 37.5, 50, 62.5, 75, 87.5, 100
Refrigerant Charge (Kg) 114 122 146 150 164 178 196
Air Cooled Heat Exchanger Ripple Aluminum Fins Around Copper Pipe
Water Cooled
Heat Exchanger
Dia.of Pipe (inch) 5" 5" 3"×2 3"×2 4"×2 4"×2 4"×2
Water Side Max Pressure  (MPa) 1
Chilled  Water Flow(m3/h) 71.38 78.43 92.36 97.70 106.64 115.58 127.28
Water Pressure Drop (kPa) 42 54 44 52 54 55 65
Flow of Hot Water(m3/h) 76.88 84.28 98.04 103.54 113.35 122.98 135.71
Axial Fan Air Flow×1000m3/h 160.8 160.8 172.8 241.2 230.4 321.6 321.6
Power×Qty (KW) 1.2×12 1.2×12 2.0×12 2.0×12 1.2×16 2.0×16 2.0×16

1. Rated Cooling Capacity Based on: DB Temperature 35ºC/WB Temperature 24ºC;Chilled water in/outlet temp. 12ºC/7ºC,  Fouling factor: 0.088.°C/KW.
2. Rated Cooling Capacity Based on: DB Temperature 7ºC/WB Temperature 6ºC;Hot water in/outlet temp. 40ºC/45ºC;  Hot water range: 45ºC~50ºC;

4.Quotation Remarks-air cooled air source heat pump
1.)Packing: Standard export package
2.)Delivery Day: 35 working days after deposit is confirmed
3.)Delivery term: CIF,FOB or CNF EX-Work are welcomed
4.)Payment term: 30% deposit by TT, the balance will be paid by TT before delivery;
  Or 100% Irrevocable non-transferred LC at sight
5.)Warranty: 12~18 months after Bill of Lading date. Any unartificial failure occurred within the period, we'll supply you the spare parts for free, and permanent technical support & consultation all life long for the machines.
6.)Validity: 20 days
7.)Payment currency: USD

























Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now