• Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
  • Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
  • Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
  • Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
  • Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
  • Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220~460V-50Hz/60Hz-3pH
Compressor Number: 1, 2, 4
Noise Level: Low
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESSA Series
Application Fields
Chemical
Application Machine
Jacketed Vessels
Certification
CE
Condition
New
Expansion Valve
Danfoss, Emerson
Refrigerant
R407c, R404A
Compressor
Copeland
Cabinet
Polyurethane Coated for Anti-Corrosion
Controller
Microcomputer Control Punp
Evaporator
Plate, Shell Tube, Coil in Tank
Condenser
Aluminum Finned Copper Tube
Color
Blue White
Tank
Stainless Steel, Unpressurized
Water Pump
Centrifugal Cnp
Solenoid Valve
Optional Castel, Hongsen
Fan
Axial
Service
OEM, ODM
Transport Package
Wooden Case
Specification
Chilled liquid outlet temp.: 0, -5, -10C
Trademark
ESACIR
Origin
Shenzhen
HS Code
8418692090
Production Capacity
3000 Units Per Year

Product Description

Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

1. Eurostars air cooled glycol chiller main components

(1)Powerful Compressor:
High performance compressor, high EER value, low power consumption, low noise, low vibration, low failure rate, life up to 15 years, smooth operation.
(2)"V"Condenser:
Large heat transfer area, more uniform heat dissipation. The heat transfer area between heat and air in the tube is accelerated to achieve the purpose of rapid heat dissipation.
(3)Pump:
It's the heart of the water cycle, 100% copper motor, no leakage, no burning machine, long life, stainless steel flexible connection for easy replacement, repair and disassembly.
(4)Intelligent Controller:
Electronic panel, intelligent control switch, intelligent operation, simple, convenient and easy maintenance. Judging the running state of the unit by display time, one-click start automatic integration of efficient work.
(5)Throttling Device:
Adopt superior quality famous exterior balanced thermal expansion valve or capillary type throttling device, which is high reliability and adjustability, can realize precise refrigerant and temperature control to ensure operating in precise and reliable status.

Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

2. Air cooled industrial glycol chiller applications
Glycol chillers are a specific kind of refrigeration system, often used to cool a variety of liquids. Using a chiller allows producers to lower the temperature of the product dramatically over a short period of time, depending on the production needs. Propylene glycol plays a significant role in the application of a glycol chiller. Glycol chillers are mainly used for jacketed vessels in the following fields:
(1)Adhesives
(2)Composites
(3)Cosmetics
(4)Fermentation
(5)Food Processing
(6)Medical
(7)Pet food processing
(8)Petrochemical
(9)Pharmaceutical

3. Air cooled glycol chiller main features
(1) Low Noise
(2) High Efficient and Energy Saving
(3) Easy Operation and Installation
(4) Compact Exterior
(5) High quality
(6) Competitive price
(7) CE certificated

4. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
Including for compressor motors, water pump motors and fan motors.
There are some situations that will cause damage to motors in an industrial chiller, such as instable voltage, ambient temperature too high which mostly caused by poor ventilation, returning water temperature too high, etc. In these cases the motor running current will get higher than its safe range, which might damage the motor if keep it working. Built in protection for overload will shut down the chiller and warn you if the motors are working unhealthily.
(2)Compressor motor overheat protection
Compressor is the heart of an industrial chiller, it reflects problem of the whole chiller unit. The situation causes compressor motor overheat includes poor ventilation, dusty condenser, refrigerant circuit blocking, lack of refrigerant, etc.
This alarm reminds you to check through the chiller unit, prevent it from burning out because of unhealthy working condition. 
(3)Discharge temperature overhigh protection
Discharge temperature overhigh normally caused by high suction temperature, high compressor motor temperature, lack of refrigerant, etc. It works as supplementary of compressor motor overheat.
(4)High&low pressure protection
High pressure normally caused by poor ventilation, dusty condenser, refrigerant circuit blocking, etc.
Low temperature caused by lack of refrigerant, system blocking and so on.
(5)Returning water overheat protection
Chiller supply cold water to cool the production process, normally the returning water temperature will be 3ºC to 8ºC higher than supplied water. If the chiller is not creating cooling energy, or the chiller capacity is not enough for the application, the temperature in the circuit will get higher and higher. This will cause damage for the production even the equipment.
While a chiller got an alarm function for returning water temperature, we can learn the situation promptly and make reaction.
(6)Low water flow/level protection
For a chiller with no open-circuit water tank, there will be a water flow switch to make sure the water circuit is working, preventing both production process and chiller unit from harmed by circuit blocking or water leaking.
(7)Phase protection
If an industrial chiller was falsely wired, motors will revert, which is a serious problem for all the motors. Phase protection will remind you to connect the power in a right way.
(8)Anti-freezing protection
This function prevents the water in the circuit from freezing, so to make sure the cooling circuit working in a healthy condition. 

5. Eurostars air cooled glycol chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit(R407C,-5ºC)
Model      ESSA- 03ISJTY 05ISJTY 08ISJTY 10ISJTY 12ISJTY 15ISJTY
Rated Cooling Capacity KW 4.69  8.02  12.40  16.60  20.30  24.00 
USRT 1.33  2.28  3.53  4.72  5.77  6.83 
×1000 kcal/h 4.03  6.90  10.66  14.28  17.46  20.64 
Air Cooled Chiller Unit(R407C,-5ºC)
Model      ESSA- 20IDJTY 25IDJTY 30IDJTY 40IQJTY 50IQJTY 60IQJTY
Rated Cooling Capacity KW 33.20  40.6 48 66.4 81.2 96
USRT 9.44  11.55  13.65  18.89  23.09  27.30 
×1000 kcal/h 28.55  34.92  41.28  57.10  69.83  82.56 

Remarks:
(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. 0ºC/-5ºC
(3)Chilled glycol-waterl iquid range: -5~5ºC; Ambient Temperature: 5ºC~43ºC.

6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards 
Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
 
7. What concentration of glycol is needed for freeze protection?
Glycol must be used in applications where the chiller is installed outdoors or when fluid temperatures below freezing are required. The freezing point of the water-glycol solution depends on the type and concentration of glycol, and whether or not the glycol contains inhibitors for corrosion protection. The table below provides a rough guide of the ethylene glycol concentration required for various ambient or operating temperatures. Choose a glycol concentration that results in a freezing point of several degrees below the lowest anticipated ambient or operating temperature.
Temperature (°C) 0 -5 -10 -15 -35
Temperature (°F) 32 23 14 5 -31
Ethylene glycol (% by volume) 20 30 30 40 55

8. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.

Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller


Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
9. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..

Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

Chiller production at our previous location as below
Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

10. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.


Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

11. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..
Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller
Chilled Liquid Outlet Low Temperature Chiller Glycol Air Cooled Chiller

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now