-15c Meat Cooling Equipment and Milk Air-Cooled Chiller

Type: Air-Cooled
Cooling Method: Air-cooled
Unit Structure: Integral
Selected Voltage: 220V/380V/400V/415V/440V-3pH-50Hz/60Hz
Compressor Number: 1 or 2
Noise Level: Low
Customization:
Diamond Member Since 2015

Suppliers with verified business licenses

Rating: 5.0/5
Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
ESGA
Application Fields
Food Processings/Chemicals/Freeze
Application Machine
CNC Machine Tools
Certification
CE
Condition
New
Cooling Type
Air Cooled
Compressor Brand
Taiwan Hanbell
Medium
Glycol Water/Brine Water
Refrigerant
R22/R404A
Compressor Type
Semi-Hermetic Screw
OEM/ODM
Available
Transport Package
Standard Export Packing, Such as Wooden Case.
Specification
CE Approval
Trademark
Eurostars
Origin
Guangdong, Prc
HS Code
8418692090
Production Capacity
200 PCS/Year

Product Description


1.Eurostars air cooled low temp glycol chiller
a)Low Noise
b)High Efficient and Energy Saving
c)Easy Operation and Installation
d)Compact Exterior
e)High quality
f)Competitive price

2.Eurostars Water Chiller Features-low temp glycol chiller
1).The Chiller cooling capacity ranged from 50Kw to 800 Kw.
2). Adopt good quality famous brand HANBELL compressor,high efficiency, low noise, less wearing and long life
3).With high efficiency condener and evaporator
4). World famous brand parts: such Danfoss/ ALCO expansion valve, FUJI contactor other brand like PUNP, Schneider,Siemens;
5). Water chillers have high COP;
6). Stable quality, long using life. 
7).Heat recovery(optional)can help user produce free hot water, which can be 55C
8). Can be widely used in different area,such as in commercial AC, Massage center, Hospital, Hotel, School, etc 
9). Strong unit base frame ensured the equipment stable operation 
10). Adopt leading brand PLC or SCM controller
11). Multi-capacity regulation, energy saving, cost cut down greatly for operation and maintenance.
12).Standard model exclude water tank and water pump;but it can be custom-made based on client requirement,such as including chilled water pump,hot water pump and hot water tank;
13).Refrigerant is R407C,R22,but R410A,R134A also available.
14).Power and frequency supply:380~415V-3PH-50HZ;Can customize 220~480V-3PH-60HZ;
15). Chilled liquid range: -15°C to 5°C
 
3.Eurostars air cooler glycol chiller technical datas:

Air Cooled Chiller Unit (Heat recovery-low temp.type/-15ºC)
Model   ESGA10SXTY15SXTY20SXTY25SXTY
10SXVTY15SXVTY20SXVTY25SXVTY
 RefrigerantR22R404AR22R404AR22R404AR22R404A
Rated cooling capacity×1000 kcal/h37.5 38.4 51.3 51.1 67.5 66.5 73.6 73.6 
kW43.6 44.6 59.7 59.4 78.5 77.3 85.6 85.6 
USRT12.4 12.7 17.0 16.9 22.3 22.0 24.3 24.3 
Comp.input PowerX QTY(KW)26.5×132.3×134.9X142.6X143.7×154.6×147.9×160.8×1
 Power supply3φ-380V-50Hz
Protection devicePhase Peversion Protection,Phase Lack Protection,Overload Current Protection,Discharge Air Temperature Protection
Number of refrigeration circuits1111
Capacity control0,66,1000,50,75,100
Refrigerant Charge(kg)25 30 42 42 
Air Coled Heat ExchangerRipple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger
Dia.Of Pipe(inch)2-1/2″2-1/2″2-1/2″3″
Water Side Max Pressure (Mpa)1
Chilled Liquid Folw (m3/h)7.5 7.7 10.3 10.2 13.5 13.3 14.7 14.7 
Water Pressure drop(Kpa)28 28 33 33 48 48 55 55 
Axial FanAir Flow×1000  m3/h28.428.440.240.240.240.256.856.8
PowerX QTY(KW)1.2×21.2×22.0×22.0×22.0×22.0×21.2×41.2×4
 Running noise dB(A)68686868
 Total Weight(kg)1180126017701900
Runnig weight(kg)1290137018602080
Heat Recovery Parameters
 Refrigerant Charge(kg)28 33 45 45 
Heaet Reciaimed Volume×1000 kcal/h11.3 11.5 15.4 15.3 20.2 19.9 22.1 22.1 
kW13.1 13.4 17.9 17.8 23.5 23.2 25.7 25.7 
USRT3.7 3.8 5.1 5.1 6.7 6.6 7.3 7.3 
Heat RecovererDia.Of Pipe(inch)1-1/2″1-1/2″1-1/2″1-1/2″
Water Side Max Pressure (Mpa)1
Reclaimed Water Flow(m3/h)2.3 2.3 3.1 3.1 4.0 4.0 4.4 4.4 
Water Pressure drop(Kpa)24 24 23 23 27 27 27 27 
 Total Weight(kg)1260134018702000
 Runnig weight(kg)1370145019602180

Air Cooled Chiller Unit (Heat recovery-low temp.type/-15ºC)
Model   ESGA30SXTY33SXTY38SXTY40SXTY
30SXVTY33SXVTY38SXVTY40SXVTY
 RefrigerantR22R404AR22R404AR22R404AR22R404A
Rated cooling capacity×1000 kcal/h89.6 88.5 98.4 99.2 116.2 114.4 122.9 121.0 
kW104.2 102.9 114.4 115.4 135.2 133.0 142.9 140.7 
USRT29.6 29.3 32.5 32.8 38.4 37.8 40.6 40.0 
Comp.input PowerX QTY(KW)58.4×171.9×163.6×180.8×171.6×192.4×175.3×197.4×1
 Power supply3φ-380V-50Hz
Protection devicePhase Peversion Protection,Phase Lack Protection,Overload Current Protection,Discharge Air Temperature Protection
Number of refrigeration circuits1111
Capacity control0,50,75,100
Refrigerant Charge(kg)48566875
Air Coled Heat ExchangerRipple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger
Dia.Of Pipe(inch)3″3″3″3″
Water Side Max Pressure (Mpa)1
Chilled Liquid Folw (m3/h)17.9 17.7 19.7 19.8 23.2 22.9 24.6 24.2 
Water Pressure drop(Kpa)61 61 64 64 66 66 66 66 
Axial FanAir Flow×1000  m3/h56.856.880.480.480.480.485.280.4
PowerX QTY(KW)1.2×41.2×42.0×42.0×42.0×42.0×41.2×62.0×4
 Running noise dB(A)72727272
 Total Weight(kg)2610270027802860
Runnig weight(kg)2830292030203250
Heat Recovery Parameters
 Refrigerant Charge(kg)51 59 71 78 
Heaet Reciaimed Volume×1000 kcal/h26.9 26.6 29.5 29.8 34.9 34.3 36.9 36.3 
kW31 31 34 35 41 40 43 42 
USRT8.9 8.8 9.8 9.8 11.5 11.3 12.2 12.0 
Heat RecovererDia.Of Pipe(inch)2″2″2″2″
Water Side Max Pressure (Mpa)1
Reclaimed Water Flow(m3/h)5.4 5.3 5.9 6.0 7.0 6.9 7.4 7.3 
Water Pressure drop(Kpa)26 26 26 26 26 26 26 26 
 Total Weight(kg)2730 2820 2900 2980 
 Runnig weight(kg)2950 3040 3140 3370 



Air Cooled Chiller Unit (Heat recovery-low temp.type/-15ºC)
Model   ESGA45SXTY50SXTY55SXTY60SXTY
45SXVTY50SXVTY55SXVTY60SXVTY
 RefrigerantR22R404AR22R404AR22R404AR22R404A
Rated cooling capacity×1000 kcal/h134.4 132.4 145.4 145.8 160.0 157.4 190.5 187.1 
kW156.3 154.0 169.0 169.6 186.1 183.1 221.6 217.6 
USRT44 44 48 48 53 52 63 62 
Comp.input PowerX QTY(KW)82.9×1106.9×190.4×1116.9×2100.6×1127.3×1116.8×1150.7×1
 Power supply3φ-380V-50Hz
Protection devicePhase Peversion Protection,Phase Lack Protection,Overload Current Protection,Discharge Air Temperature Protection
Number of refrigeration circuits1111
Capacity control0,50,75,100
Refrigerant Charge(kg)80 86 95 105 
Air Coled Heat ExchangerRipple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger
Dia.Of Pipe(inch)4″4″4″4″
Water Side Max Pressure (Mpa)1
Chilled Liquid Folw (m3/h)26.9 26.5 29.1 29.2 32.0 31.5 38.1 37.4 
Water Pressure drop(Kpa)42 42 54 54 44 44 52 52 
Axial FanAir Flow×1000  m3/h85.285.2120.6120.6120.6120.6160.8160.8
PowerX QTY(KW)1.2×61.2×62.0×62.0×62.0×62.0×62.0×82.0×8
 Running noise dB(A)72727272
 Total Weight(kg)3220324035003620
Runnig weight(kg)3380362038804010
Heat Recovery Parameters
 Refrigerant Charge(kg)85 91 100 110 
Heaet Reciaimed Volume×1000 kcal/h40.3 39.7 43.6 43.7 48.0 47.2 57.2 56.1 
kW47 46 51 51 56 55 66 65 
USRT13.3 13.1 14.4 14.5 15.9 15.6 18.9 18.6 
Heat RecovererDia.Of Pipe(inch)2-1/2″2-1/2″2-1/2″2-1/2″
Water Side Max Pressure (Mpa)1
Reclaimed Water Flow(m3/h)8.1 7.9 8.7 8.7 9.6 9.4 11.4 11.2 
Water Pressure drop(Kpa)26 26 26 26 27 27 27 27 
 Total Weight(kg)3360 3390 3650 3770 
 Runnig weight(kg)3520 3770 4030 4160 


Air Cooled Chiller Unit (Heat recovery-low temp.type/-15ºC)
Model   ESGA50DXTY60DXTY65DXTY
50DXVTY60DXVTY65DXVTY
 RefrigerantR22R404AR22R404AR22R404A
Rated cooling capacity×1000 kcal/h147.0 147.0 179.1 177.0 196.8 198.4 
kW171.0 171.0 208.3 205.9 228.9 230.7 
USRT49 49 59 59 65.1 65.6 
Comp.input PowerX QTY(KW)47.9×260.8×258.4×271.9×263.6×280.8×2
 Power supply3φ-380V-50Hz
Protection devicePhase Peversion Protection,Phase Lack Protection,Overload Current Protection,Discharge Air Temperature Protection
Number of refrigeration circuits222
Capacity control0,25,37.5,50,62.5,75,87.5,100
Refrigerant Charge(kg)110115124
Air Coled Heat ExchangerRipple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger
Dia.Of Pipe(inch)4″4″4″
Water Side Max Pressure (Mpa)1
Chilled Liquid Folw (m3/h)29.4 29.4 35.8 35.4 39.4 39.7 
Water Pressure drop(Kpa)54 54 55 55 65.0 65.0 
Axial FanAir Flow×1000  m3/h113.6113.6113.6113.6160.8 160.8 
PowerX QTY(KW)1.2×81.2×81.2×81.2×82.0×82.0×8
 Running noise dB(A)757575
 Total Weight(kg)459047804850
Runnig weight(kg)476049505130
Heat Recovery Parameters
 Refrigerant Charge(kg)115120129
Heaet Reciaimed Volume×1000 kcal/h44.1 44.1 53.7 53.1 59.0 59.5 
kW51 51 63 62 68.7 69.2 
USRT14.6 14.6 17.8 17.6 19.5 19.7 
Heat RecovererDia.Of Pipe(inch)2-1/2″2-1/2″2-1/2″
Water Side Max Pressure (Mpa)1
Reclaimed Water Flow(m3/h)8.8 8.8 10.7 10.6 11.8 11.9 
Water Pressure drop(Kpa)30 30 30 30 34.0 34.0 
 Total Weight(kg)475049405010
 Runnig weight(kg)492051105290


Air Cooled Chiller Unit (Heat recovery-low temp.type/-15ºC)
Model   ESGA75DXTY80DXTY90DXTY
75DXVTY80DXVTY90DXVTY
 RefrigerantR22R404AR22R404AR22R404A
Rated cooling capacity×1000 kcal/h232.5 228.8 245.6 241.9 268.8 264.7 
kW270.5 266.1 285.7 281.3 312.6 307.8 
USRT77 76 81 80 88.9 87.5 
Comp.input PowerX QTY(KW)71.6×292.4×275.3×297.4×282.9×2106.9×2
 Power supply3φ-380V-50Hz
Protection devicePhase Peversion Protection,Phase Lack Protection,Overload Current Protection,Discharge Air Temperature Protection
Number of refrigeration circuits222
Capacity control0,25,37.5,50,62.5,75,87.5,100
Refrigerant Charge(kg)135147161
Air Coled Heat ExchangerRipple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger
Dia.Of Pipe(inch)4″4″4″
Water Side Max Pressure (Mpa)1
Chilled Liquid Folw (m3/h)46.5 45.8 49.1 48.4 53.8 52.9 
Water Pressure drop(Kpa)54 54 55 55 65.0 65.0 
Axial FanAir Flow×1000  m3/h160.8160.8170.4170.4170.4 170.4 
PowerX QTY(KW)2.0×82.0×81.2×121.2×121.2×121.2×12
 Running noise dB(A)757575
 Total Weight(kg)536055105660
Runnig weight(kg)558058306100
Heat Recovery Parameters
 Refrigerant Charge(kg)140152166
Heaet Reciaimed Volume×1000 kcal/h69.8 68.6 73.7 72.6 80.6 79.4 
kW81 80 86 84 93.8 92.3 
USRT23.1 22.7 24.4 24.0 26.7 26.3 
Heat RecovererDia.Of Pipe(inch)2-1/2″2-1/2″2-1/2″
Water Side Max Pressure (Mpa)1
Reclaimed Water Flow(m3/h)14.0 13.7 14.7 14.5 16.1 15.9 
Water Pressure drop(Kpa)30 30 30 30 34.0 34.0 
 Total Weight(kg)552056705820
 Runnig weight(kg)574059906260

Air Cooled Chiller Unit (Heat recovery-low temp.type/-15ºC)
Model   ESGA95DXTY105DXTY125DXTY
95DXVTY105DXVTY125DXVTY
 RefrigerantR22R404AR22R404AR22R404A
Rated cooling capacity×1000 kcal/h290.7 291.7 319.9 314.9 381.1 374.3 
kW338.1 339.3 372.1 366.2 443.2 435.3 
USRT96 96 106 104 126.0 123.8 
Comp.input PowerX QTY(KW)90.4×2116.9×2100.6×2127.3×2116.8×2150.7×2
 Power supply3φ-380V-50Hz
Protection devicePhase Peversion Protection,Phase Lack Protection,Overload Current Protection,Discharge Air Temperature Protection
Number of refrigeration circuits222
Capacity control0,25,37.5,50,62.5,75,87.5,100
Refrigerant Charge(kg)175186195
Air Coled Heat ExchangerRipple Aluminum Fins Around Copper Pipe

Water Cooled Heat Exchanger
Dia.Of Pipe(inch)4"4"4″×2
Water Side Max Pressure (Mpa)1
Chilled Liquid Folw (m3/h)58.1 58.3 64.0 63.0 76.2 74.9 
Water Pressure drop(Kpa)54 54 55 55 65.0 65.0 
Axial FanAir Flow×1000  m3/h241.2241.2241.2241.2321.6 321.6 
PowerX QTY(KW)2.0×122.0×122.0×122.0×122.0×162.0×16
 Running noise dB(A)757575
 Total Weight(kg)572058606320
Runnig weight(kg)604064806900
Heat Recovery Parameters
 Refrigerant Charge(kg)180191200
Heaet Reciaimed Volume×1000 kcal/h87.2 87.5 96.0 94.5 114.3 112.3 
kW101 102 112 110 133.0 130.6 
USRT28.8 28.9 31.7 31.2 37.8 37.1 
Heat RecovererDia.Of Pipe(inch)2-1/2″2-1/2″2-1/2″×2
Water Side Max Pressure (Mpa)1
Reclaimed Water Flow(m3/h)17.4 17.5 19.2 18.9 22.9 22.5 
Water Pressure drop(Kpa)30 30 30 30 34.0 34.0 
 Total Weight(kg)588060206480
 Runnig weight(kg)620066407060

NOTE:
1. Rated Cooling Capacity Based on: DB Temperature 35ºC/WB Temperature 24ºC
Chilled water in/outlet temp. -10ºC/-15ºC, Fouling factor: 0.088.°C/KW.
2. Chilled Water Range: -15~-5ºC; Ambient Temperature: 5ºC~43ºC;
3. Heat recovery unit water in/out temperature: 50ºC/55ºC;
4. Specifications are subject to change without notice for further improvement.


4.Eurostars water chiller protection devices
1)Phase reversion protection, 
2)Phase lack protection, 
3)Overload current protection,
4)Discharge air temp. protection, 
5)Low & High pressure protection, 
6)Low temp. protection,